Accuracy Testing Device
Model :
SHK30/SHK40/SHK50
Operqation instruction
A. Check and ensure the aligner bar is standard. Turn the spindle and check if it is clean.
B. Position the fixing keyways on spindle, turn right and fix the spindle.
C. Fix the aligner bar on the spindle, (depth 15mm) and tighten the fixing nut.
D. Turn the fixing key to the left. Turn the spindle.
E. Place the meter at the testing position. Test and align.
F. The highest position of the testing bar is the contact point.
Remarks
- Place the aligner seat on the bracket.
- Keep the room temperature within 20°C±10°C.
- Do not knock or touch the aligner seat.
- Keep the device clean and proceed routine maintenance.

Spindle testing bar is available on request.
Unit:mm
Model | Taper | A | Weight (kg) | Rod screw(M/Inch) |
---|---|---|---|---|
SHK-30 | NT30 / BT30 | 500 mm | 49 / 55 | M12 × 1.75 / 1/2" |
SHK-40 | NT40 / BT40 | 500 mm | 67 / 74 | M16 × 2.0 / 5/8" |
SHK-50 | NT50 / BT50 | 700 mm | 109 / 117 | M24 × 3.0 / 1" |